Instrument calibration for Selangor and Kuala Lumpur
Weighing, temperature, pressure, dimensional, electrical and laboratory instruments — calibrated in the lab or at your site.
Start from your industry
- Mettler Toledo
- Sartorius
- Ohaus
- A&D
- Eppendorf
- Gilson
- Fluke
- Testo
- WIKA
- Mitutoyo
- Hioki
- Tohnichi
We also calibrate instruments from other makers. Trademarks and logos belong to their respective owners.
Browse by instrument type
One quotation can cover instruments of any type.
From your instrument list to your next calibration date
- 01
Send your list
Add instruments to a quote list, or email us what you have.
- 02
Receive a quotation
Scope, method, turnaround and price for each item.
- 03
Calibration
In the lab or at your site. We can collect and return within the Klang Valley.
- 04
Certificate and reminder
Issued electronically. If you opt in, we remind you before the next due date.
What every certificate records
- 01Instrument, range and serial number
- 02Readings before and after adjustment
- 03Error and measurement uncertaintyHow far the true value could be from the reading, at about 95% confidence (k = 2).
- 04Test conditions, method and the reference used
- 05Recalibration due date, on request
| Nominal | As found | As left | Error | Uncertainty |
|---|---|---|---|---|
| 0.000 | 0.0004 | 0.0001 | 0.0001 | ±0.0018 |
| 5.000 | 5.0021 | 5.0003 | 0.0003 | ±0.0018 |
| 12.500 | 12.5038 | 12.5006 | 0.0006 | ±0.0018 |
| 25.000 | 25.0052 | 25.0009 | 0.0009 | ±0.0018 |
Values in mm. Uncertainties stated at a coverage probability of approximately 95%, k = 2. Sample layout for illustration — not issued to any customer.
Not yet accredited
We are working towards SAMM accreditation to ISO/IEC 17025:2017. We will publish the accreditation number and scope here once it is granted. Until then, our certificates do not carry the SAMM mark.
- Standard
- ISO/IEC 17025:2017
- Scheme
- SAMM, Department of Standards Malaysia
- Status
- Not yet granted
Before you book
Do you calibrate in the laboratory or on site?
Handheld and benchtop instruments are calibrated in the lab. Installed or heavy equipment — floor scales, ovens, autoclaves, cold rooms, freezers — is calibrated at your site. The instrument list marks which is which.
How long does it take?
Your quotation states the return date for each item, counted from when we receive the instrument and your confirmation. Urgent and express turnaround are available at a surcharge.
Can you collect and return instruments?
Yes, within the Klang Valley. The charge is itemised on your quotation.
How often should an instrument be recalibrated?
Your quality system, regulator or the manufacturer sets the interval; twelve months is common. Give us your interval and we show the due date on the certificate.
Is calibration the same as verification under the Weights and Measures Act 1972?
No. Weighing instruments used for trade must be verified and stamped by the government-appointed agency. Our certificate records error and uncertainty; it does not replace legal verification.
My instrument is not listed. Can you still calibrate it?
Add it to the notes of your quote request. We will confirm whether we can calibrate it before you book.