Precision in every measurement

Instrument calibration for Selangor and Kuala Lumpur

Weighing, temperature, pressure, dimensional, electrical and laboratory instruments — calibrated in the lab or at your site.

Makes we calibrate
  • Mettler Toledo
  • Sartorius
  • Ohaus
  • A&D
  • Eppendorf
  • Gilson
  • Fluke
  • Testo
  • WIKA
  • Mitutoyo
  • Hioki
  • Tohnichi

We also calibrate instruments from other makers. Trademarks and logos belong to their respective owners.

How it works

From your instrument list to your next calibration date

  1. 01

    Send your list

    Add instruments to a quote list, or email us what you have.

  2. 02

    Receive a quotation

    Scope, method, turnaround and price for each item.

  3. 03

    Calibration

    In the lab or at your site. We can collect and return within the Klang Valley.

  4. 04

    Certificate and reminder

    Issued electronically. If you opt in, we remind you before the next due date.

Your certificate

What every certificate records

  1. 01
    Instrument, range and serial number
  2. 02
    Readings before and after adjustment
  3. 03
    Error and measurement uncertaintyHow far the true value could be from the reading, at about 95% confidence (k = 2).
  4. 04
    Test conditions, method and the reference used
  5. 05
    Recalibration due date, on request
Sample layout. Values are illustrative and do not describe a real calibration.
Certificate of calibration — sample layout
DC-0000-00000 · SAMPLE
InstrumentMicrometer, external
Range0–25 mm
Serial no.SAMPLE-001
Conditions20.0 °C, 45% RH
MethodGauge block comparison
Reference standardGauge block set, grade 0
NominalAs foundAs leftErrorUncertainty
0.0000.00040.00010.0001±0.0018
5.0005.00215.00030.0003±0.0018
12.50012.503812.50060.0006±0.0018
25.00025.005225.00090.0009±0.0018

Values in mm. Uncertainties stated at a coverage probability of approximately 95%, k = 2. Sample layout for illustration — not issued to any customer.

Accreditation

Not yet accredited

We are working towards SAMM accreditation to ISO/IEC 17025:2017. We will publish the accreditation number and scope here once it is granted. Until then, our certificates do not carry the SAMM mark.

Standard
ISO/IEC 17025:2017
Scheme
SAMM, Department of Standards Malaysia
Status
Not yet granted
Questions

Before you book

Do you calibrate in the laboratory or on site?

Handheld and benchtop instruments are calibrated in the lab. Installed or heavy equipment — floor scales, ovens, autoclaves, cold rooms, freezers — is calibrated at your site. The instrument list marks which is which.

How long does it take?

Your quotation states the return date for each item, counted from when we receive the instrument and your confirmation. Urgent and express turnaround are available at a surcharge.

Can you collect and return instruments?

Yes, within the Klang Valley. The charge is itemised on your quotation.

How often should an instrument be recalibrated?

Your quality system, regulator or the manufacturer sets the interval; twelve months is common. Give us your interval and we show the due date on the certificate.

Is calibration the same as verification under the Weights and Measures Act 1972?

No. Weighing instruments used for trade must be verified and stamped by the government-appointed agency. Our certificate records error and uncertainty; it does not replace legal verification.

My instrument is not listed. Can you still calibrate it?

Add it to the notes of your quote request. We will confirm whether we can calibrate it before you book.